日本SMC小型數(shù)字式壓力表圖片
上海乾拓貿(mào)易有限公司
電話:021-39526589-8004
手機(jī):17321056802 (微信)
郵箱:17321056802@163.com
企業(yè)QQ:2880626084
聯(lián)系人:楊江玲
地址:上海嘉定區(qū)嘉涌路99弄6號樓713室
Please note that the accuracy of measurement for other fluids cannot be guaranteed.
with one touch switching of the display from peak value to bottom value.
Power turns off automatically if not operated for more than 5 minutes.
The case holder is provided as an option to allow for situations where portability is not required.
Over pressure, Memory data error, Change battery sign
200 kPa Air, Non-corrosive gases, Nonflammable gas 3 V (DC), Type AA dry cell x 2 pcs. 12 months continuous operation
–10 to 100 kPa
One year of continuous operation is possible with 2 type AA batteries (3 V).
Keeping practical use in mind, the hand strap is a standard feature.
before using a produc t. Also, keep the manual in a location where it can be referred to at any time
(Temperatue conditions: at 25°C) ±1% F.S. or less (Temperatue conditions: at 25°C)
Peak/bottom display, Backlight, Auto power OFF Zero clear, Units display switching
PPA101 for vacuum PPA102 for low press.
1.5 MPa 200 kPa
? 2 pcs. of type AA dry batteries (manganese R6 or alkaline LR6) are not included. Note
1) For the unit switching function (Types without the unit switching function is fixed in SI unit (kPa or MPa).)
kPa MPa mmHg kgf/cm2 inHg psi bar
4. When installing or removing One-touch fittings on tubing,
first confirm that the fluid to be measured is at atmospheric pressure.
If tubing is disconnected while the fluid to be measured is in a pressurized state,
the tubing may jump causing a danger of injury or damage. Also when connecting tubing, confirm that it is securely attached.
1 — — 0.01 — 0.1 0.01
PPA100/101/102 Series PPA Compact Manometer
Note) Fixed unit For vacuum/compound pressure: kPa For positive pressure: MPa
. The compact manometer can be used for measurement of air and non-corrosive gases.
±3% F.S. or less (0 to 50°C with 25°C standard) M5 x 0.8 0 to 50°C (With no condensation) 35 to 85% RH
(With no condensation) 980 m/s2 X, Y, Z directions, 3 times each (De-energized) IP40 (IEC standard) Approx. 100 g (Unit 50 g, batteries 50 g)
–0.1 to 1 MPa PPA100 for high press.
Offset adjustment with the zero clear function, and span calibration with the trimmer can be performed.
With pressure being displayed, variations in supply pressure can be grasped instantly
1 — 5 0.01 0.2 0.1 0.01
(Without backlighting, temperature conditions: at 25°C) 250 ms ±2% F.S. or less
Furthermore, the construction is not explosion proof, and therefore, flammable gases should not be used.
5. Instruction manual Read it carefully and understand the contents
— 0.01 — 0.1 — 1 0.1
2. Be certain to stay within the rated pressure range. Operation outside the pressure range will cause failure.
3. Do not intentionally swing around by the hand strap. If the strap breaks or comes loose, there is a danger of injury or damage, etc.
日本SMC小型數(shù)字式壓力表圖片
021-39526589
網(wǎng)址:czhfh.cn
地 址:上海市嘉定區(qū)嘉涌路99弄
6號樓713室